Saffire
NEWS
|
|||||||||||||||||||||||||
|
BS
EN ISO 2503 : 1998
"Pressure regulators for gas cylinders used in welding cutting and allied processes up to 300 bar" |
|||||||||||||||||||||||||
|
CHANGES
TO REGULATOR MARKINGS
|
|||||||||||||||||||||||||
| The above
standard has now been fully adopted in the UK and the equivalent British
Standards withdrawn. This document covers all regulators used in welding
and cutting applications. The requirements for marking the operational data on regulators has changed and now requires the following: "....the information shall be clearly and permanently marked on the pressure regulator body or cover or on a label which is permanently fixed to the regulator". In order to comply with this direction, Murex regulators will be modified to allow the information to be indelibly stamped onto the body. The benefits are that it is permanent and will remain visible throughout the working life of the regulator. The data will be positioned on the back of the regulator body in the following format: |
|||||||||||||||||||||||||
|
TYPICAL OXYGEN REGULATOR MARKINGS |
|||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||
|
WHAT
DO THESE MEAN?
|
|||||||||||||||||||||||||
| GAS TYPE | |||||||||||||||||||||||||
| Each gas is now designated by a code letter. | |||||||||||||||||||||||||
|
CODE
LETTERS FOR GASES TO BE USED FOR MARKING OF PRESSURE REGULATORS
|
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
| STANDARD | |||||||||||||||||||||||||
| This guarantees that the regulator meets all the requirements of EN ISO 2503. Due to increase cylinder filling pressures in UK only regulators conforming to the current EN Standard should be used. | |||||||||||||||||||||||||
|
CLASS,
MAXIMUM INLET PRESSURE AND MAXIMUM OUTLET PRESSURE
|
|||||||||||||||||||||||||
| The table below shows the various regulator classes and the service ratings. | |||||||||||||||||||||||||
|
EQUIPMENT
CLASSES
|
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
5
YEAR REPLACEMENT,
|
|||||||||||||||||||||||||
| In line with the recommendations of BCGA Code of Practice 7, Pressure regulators should be replaced or refurbished after 5 years in service. This mark is a convenient way to identify the required replacement date ie 2004 would be shown on the body. | |||||||||||||||||||||||||
| DATE STAMP | |||||||||||||||||||||||||
| This is a Quality Control Code to identify the precise date upon which the unit was manufactured. | |||||||||||||||||||||||||
|
THE
MUREX PRODUCT RANGE WILL HAVE 4 BASIC BODY STAMPINGS
|
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
Examples
of the body stampings
|
|||||||||||||||||||||||||